HEFA 5T AH

HEFA 5T Air Handler

Technical Specs:
  • Cooling Output Tons: 5 tons
    • Based on 44°F (6°C) supply fluid and 95°F (35°) ambient air
    • 900 CFM air flow and 12 GPM fluid flow
  • Heating Output BTU: 91,731 Btu/h
    • Based on 180°F (82°C) supply fluid and 32°F (0°C) ambient air
  • Blower:
    • Backward inclined
  • Motor: 0.6 HP, variable speed
  • Electrical: 120V, single phase, 60 Hz, 15 A
  • Controls:  Thermostatic and fan speed
  • Weight: 130 lbs (59 kg)
  • Dimensions: 29″ l x 18.5″ w x 28.5″ h
  • Circulation: Single supply and return
    • 3/4″ quick couplers (standard)
  • Condensate pump: 3/4″ drain hose connection

View Product

HEFA 25T AH

HEFA 25T Air Handler

Technical Specs:
  • Cooling Output Tons: 25 tons
    • Based on 45°F (7°C) supply fluid and 95°F (35°) ambient air
    • 4,600 CFM air flow and 70 GPM fluid flow
  • Heating Output BTU: 512,418 Btu/h
    • Based on 200°F (93°C) supply fluid and 32°F (0°C) ambient air
  • Blower:
    • Motorized impeller
  • Motor: 1 HP, variable speed
  • Electrical: 120V, single phase, 60 Hz, 20 A
  • Controls:  Thermostatic and fan speed
  • Weight: 755 lbs (343 kg)
  • Dimensions: 68″ l x 33″ w x 67″ h
  • Circulation: Single supply and return
    • 2″ quick couplers (standard)
  • Condensate pump: 3/4″ drain hose connection

View Product

2000 HHP-E

2000 HHP-E Hydro Heat Pro Electric

Technical Specs:
  • Fluid temperature range: 80°F to 180°F
  • Water heaters x2: 600 kW Electric
  • Output capacity: 2,000,000 BTU (59 HP)
  • Circulation pump: 5 HP, 160 US GPM @ 30 PSI
  • Electrical: 480 V, 3-phase, 60 Hz
    • MOCP: 1,000 AMP
    • MCA: 750 AMP
    • Staging: 30 stages at 20 kW load steps
  • Circulation System
    • Plate heat exchanger x2: 2,000,000 BTU
    • Pumps x2: 3 HP, 110 US GPM @ 30 PSI
  • Primary lines: 2″ fluid circulation lines
  • Primary connections: 2″ BV, 2” Kamlok® QC
  • Weight: 9,500 lbs (4,300 kg)
    • Tongue weight: 1,100 lbs (500 kg)
  • Dimensions: 212″ L x 93.5″ W x 110″ H

View Product

HEFA 3200 MAXCOIL

Technical Specs:
  • BTU Output: 1,200,000 Btu/h (600,000 Btu each
    • Based on 200°F (93°C) supply fluid and 50°F (10°C) ambient air
    • 15,200 CFM (7,600 CFM each), Static Pressure: 1.67 in.wc, 1700 RPM
  • Motor: 2x 3 HP
  • Power Requirements: 2x 230V, single phase, 30 A
  • Controls: Thermostatic temperature control
  • Weight: 1,500 lbs (680 kg) (750 lbs 340kg each)
  • Dimensions: 67″L x 34″W x 96″H (50″H each)

View Product

MultiMax unit

MultiMax System

Deliver up to 7 million BTU’s of heat to the tank for fluid heating or frost prevention using: 4x 900 Central Heating Units (CHUs) A proprietary boosting system Large stainless steel heat plates

View Product

600 CHU Central Heating Unit

Technical Specs:
  • FUEL – Diesel, #1 or 2 Heating Oil
  • Tri-fuel Version – Diesel, LP or NG
  • OUTPUT BTU/H – 620,200
  • FUEL CAPACITY – 130 US GAL./492 L
  • HEAT SQ.FT. – 19,000
  • THAW SQ.FT. – 11,250
  • CURE SQ.FT. – 25,000

*Burner change required for 0600 Tri-fuel model to switch between different fuels.

View Product

1800 HHP Hydro Heat Pro

1800 HHP Hydro Heat Pro

Technical Specs:
  • Tri-Fuel: Diesel, LP or NG
  • Input:
    • Diesel: 1,792,000 Btu/h
    • LP: 1,715,000 Btu/h
    • NG: 1,690,000 Btu/h
  • Weight: 9,000 lbs
  • Dimensions: 212″ l x 93.5″ w x 114″ h
  • Optional lift frame available

* Burner change required to switch fuel source.

View Product

900 HCP Heat Center Pro

Technical Specs:
  • Tri-Fuel: Diesel, LP or NG
  • Input:
    • Diesel: 896,000 Btu/h
    • LP: 857,500 Btu/h
    • NG: 845,000 Btu/h
  • Weight: 8,422 lbs
  • Dimensions: 218″ l x 94″ w x 106″ h
  • Optional lift frame available

* Burner change required to switch fuel source. 

View Product

HEFA ES 200 Fan Coil

Technical Specs:
  • BTU Output: 201,364 Btu/h
    • Based on 200°F (93°C) supply fluid and 32°F (0°C) ambient air
    • 2,300 CFM air flow at 1.67″ w/c 15 GPM fluid flow
  • Fan: Backward inclined
  • Motor: 1 HP, variable speed
  • Power Requirements: 120V, single phase, 60 Hz
  • Controls: Thermostatic temperature control
  • Weight: 244 lbs (111 kg)
  • Dimensions: 43.25″ l x 25.5″ w x 44″ h
  • Fluid Lines: 300 PSI heavy-duty “Explorer Air” hose 1″ I.D. x 50′ (15.2 m)

View Product

400 CHU Central Heating Unit

Technical Specs:
  • Fuel: LP, NG or Tri-Fuel: Diesel, LP or NG
  • Input: 354,960 Btu/h
  • Heat Area: 11,000 ft²
  • Thaw Area: 6,000 ft²
  • Cure Area: 14,000 ft²
  • Weight: 1,370 lbs
  • Dimensions: 51″ l x 48″ w x 74″ h

* Burner change required to switch fuel source. 

View Product

200 GTS GreenThaw

200 GTS GreenThaw™ System

Technical Specs:
  • Fuel: Diesel
  • Input: 212,800 Btu/h
  • Fuel Capacity: 80 US gal
  • On-board Hose: 3/4″ 600 ft (std), 1,200 ft*
  • Heat Area: 6,000 ft²
  • Thaw Area: 1,800 ft² (std), 3,600 ft²*
  • Cure Area: 2,400 ft² (std), 7,200 ft²*
  • Weight: 4,315 lbs
  • Dimensions: 122/166″ l x 76″ w x 92″ h
    (Length with tow pole up/down)
  • Integrated lift frame

* Additional hose and accessories are used to reach the maximum thawing and curing capabilities listed above.

View Product