HEFA 600 Fan Coil
Technical Specs:
- BTU Output: 512,418 Btu/h
- Based on 200°F (93°C) supply fluid and 32°F (0°C) ambient air
- 5,000 CFM air flow and 30 GPM fluid flow
- Blower:
- Axial Flow
- Output – 5,000 CFM
- Motor: 1 HP, 3-Speed
- Power Requirements: 120V, single phase, 60 Hz, 12.7A
- Weight: 560 lbs (254 kg)
- Dimensions: 81″ l x 45″ w x 52″ h
- Fluid Lines: 1 1/4″ I.D. w/ 1″ hydraulic style quick couplers
- BTU Output: 512,418 Btu/h
-

600 RTS GreenDry System
Technical Specs:
Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer. Largest capacity heater in its class… -

Hose Reels
Technical Specs:
Hose storage with unique” auto-feed system makes laying out hose on a job site a one-man operation… -

DECU 1000 Drying Environmental Control Unit
Technical Specs:
The DECU1000 is a fan-coil type liquid-to-air heat exchanger with high efficiency air filtering capabilities and a full, versatile control system -

Plate Heat Exchanger – HEFF 1M Series II
Technical Specs:
Heat delivery on a muti-storied project while still keeping the heat source at ground level. Heat transfer fluid can be circulate up to 70 feet (21 M) above the central heating module´s elevation utilizing our standard primary fluid lines. -

2000 Series 1200 CHU Central Heating Unit
Technical Specs:
- Fuel: LP or NG
- Input: 1,233,000 Btu/h
- Heat Area: 40,000 ft²
- Thaw Area: 21,750 ft²
- Cure Area: 48,000 ft²
- Weight: 1,815 lbs
- Dimensions: 104″ l x 45″ w x 134″ h
- Optional lift frame available
-

2100 series 1800 DG CHU Central Heating Unit
Technical Specs:
- Fuel: LP, NG or Tri-Fuel: Diesel, LP or NG
- Input: 1,792,000 Btu/h
- Heat Area: 54,000 ft²
- Thaw Area: 32,250 ft²
- Cure Area: 72,000 ft²
- Weight: 3,840 lbs
- Dimensions: 88″ l x 48″ w x 97″ h
- Optional lift frame available
-

Fluid Circulation Components
Technical Specs:
- Primary and secondary circulation lines
- fluid distribution manifolds
- All fluid distribution system components employ quick-coupler connections and remains fully charged for quick setup-and-go operation.
- An assortment of tees and fittings are also available… allowing the widest range of setup possibilities.
-

HESF-1000 Central Heating Unit
Technical Specs:
- Heat Source: Low-pressure steam
- Input: 1,000,000 Btu/h
- Heat Area: 40,000 ft²
- Thaw Area: 18,000 ft²
- Cure Area: 48,000 ft²
- Weight: 405 lbs
- Dimensions: 47″ l x 28″ w x 75″ h